History imc CANSAS Release Cansas 2.3 R1 November 17 2023 -------------------------------------------------------------------------------- 10/2023: - [CANSAS] added support for the Vector-CAN-Interface VN7640 - [CANSAS] supplied driver for KVASER now also supports CAN/USB interface U100 - [CANSAS\DCB-8] fixed issue with balancing on channels attached to connector 2 and 4 - [CANSASfdx-FBGT-8] fixed issue when values are not directly visible in the channel view after changing the measurement range - [CANSASfdx-FBGT-8] added setting to measure temperatures in Fahrenheit - [CANSASfit-HISO-T8] added setting to measure temperatures in Fahrenheit - [CANSASfit-HISO-UT6] added setting to measure temperatures in Fahrenheit - [CANSASfit-T10] added setting to measure temperatures in Fahrenheit - [CANSASfit-UTI6] added setting to measure temperatures in Fahrenheit - [CANSASfit] added compatibility to imcDeviceCore for all CANSASfit modules (requires a firmware update) - [CANSASflex-L-CI8] fixed issue with channel names when selecting multiple channels Release Cansas 2.2 R13 August 24 2023 -------------------------------------------------------------------------------- 08/2023: - [CANSASfdx-FBGT-8] added single point calibration - [CANSAS] added missing image in module integration assistant - [CANSAS] fixed issue when module configuration was required after printing - [CANSAS] fixed issue in scaling setting (UTI-6) - [CANSAS] removed imc CAN/USB Interface from CANSAS setup - [CANSAS] added baudrate setting in DBC export Release Cansas 2.2 R12 March 30 2023 -------------------------------------------------------------------------------- 03/2023: - [CANSASfit-SER4] new module is now supported - [CANSAS] added digital signature for executable files Release Cansas 2.2 R11 November 14 2022 -------------------------------------------------------------------------------- 11/2022: - [CANSASfit-HISO-UTI6] firmware for new hardware revisions - [CANSASfit-HISO-T-8] firmware for new hardware revisions - [CANSASfit-HISO-HV4] firmware for new hardware revisions - [CANSAS DI8] fixed issue when displaying the leds in the CANSAS GUI - [CANSASflex UNI8] fixed issue when updating to CANSAS 2.2R7 - New manual edition Release Cansas 2.2 R10 September 20 2022 -------------------------------------------------------------------------------- 09/2022: - [CANSAS] fixed an issue with duplicate message identifiers - [CANSAS DI8] new module is now supported - [CANSASfit-DI16] firmware for new hardware revisions - [CANSASfit-ENC] firmware for new hardware revisions - [CANSASfit-T10] firmware for new hardware revisions - [CANSASfit-UTI-6] firmware for new hardware revisions - [CANSASflex-L-P8-GX] added new nipple types - New manual edition Release Cansas 2.2 R9 dated August 16 2022 -------------------------------------------------------------------------------- 08/2022: - [CANSASfit-HISO-T-8] firmware for new hardware revision - [CANSAS] fixed issue when importing and exporting module configurations (fit-modules) Release 2.2 R8 dated May 25 2022 -------------------------------------------------------------------------------- 05/2022: - [CANSASfit-ENC] fixed issue in transceiver-unlocking - [CANSAS] fixed issue in module integration Release 2.2 Rev 7 dated March 4 2022 -------------------------------------------------------------------------------- 02/2022: - [CANSAS\DCB-8] added option to keep balancing values when re-configuring - [CANSAS\UNI-8] added option to keep balancing values when re-configuring - [CANSASfit-HISO-HV4] Heartbeat functionality added - [CANSASfit-HISO-T-8] Heartbeat functionality added - [CANSASfit-HISO-U-6] Heartbeat functionality added - [CANSASfit-T10] Heartbeat functionality added - [CANSASfit-UTI-6] Heartbeat functionality added - [CANSASfit-ENC] Heartbeat functionality added - [CANSASfit-DI16] Heartbeat functionality added - [CANSASfdx-FBGT-8] Heartbeat functionality added - [CANSASflex-HISO-8] module hardware does not support sensor reading / writing - [CANSASflex-HISO-HV4] new module is now supported - [CANSASfit-T-8] fixed issue with displaying channel names 03/2022: New manual edition Release V2.2 Rev 6 dated December 6 2021 -------------------------------------------------------------------------------- 11/2021: - [CANSASfit-HISO-T-8-2L] Sensor read/write is not supported and removed from the CANSAS GUI - [CANSASfit-HISO-UT-6-3L] Settings for supply voltage corrected - [CANSASflex-L-SC16-L-0B-PT] unsupported measurement modes are removed from the CANSAS GUI - [CANSASflex-L-CI8-L-1S-PT] new front panel type added - [CANSASflex-L-CI8-NTC850K] new front panel type added - [CANSASflex-L-CI8-PT] connection diagrams updated 12/2021: New manual edition Release V2.2 Rev 5 dated October 28 2021 -------------------------------------------------------------------------------- 09/2021: new firmware for CANSASfit-HISO-UT6 - Overrange detection implemented for hardware revision 4 (MSIM_GR2_3) 10/2021: CANSASfit-HISO-T-8-2L - Firmware for hardware revision 4 implemented (MSIM_GR2_3) - Copy of configuration from different hardware-revisions implemented 10/2021: Japanese GUI updated Release V2.2 Rev 4 dated August 10 2021 -------------------------------------------------------------------------------- 03/2021: Integration of the product "CANSASfit-UTI-6-ODU5-SUP-PWR" into imc CANSAS - Support of Profil-ID 0x00210400 (UTI-6-ODU5-SUP-PWR) - Functional scope/firmware etc. identical to 0x00208400 (UTI-6-ODU5-SUP) 04/2021: LabView-VI for CANSAS CI-8; setting for thermocouple-type corrected 06/2021: Software: CANSASfit-HISO-T8 MSIM_GR2_3 Software: CANSASfit-HISO-UT6 MSIM_GR2_3 08/2021: Integration of the product "CANSASfit-UTI-6-ODU5-SUP-PWR" into imc CANSAS - like UTI-6-ODU5-SUP, but without adjustable power supply, which is always active. 08/2021: UTI-6, balancing in the Measurement dialog now works without any restrictions. Release V2.2 Rev 3 dated December 11 2020 -------------------------------------------------------------------------------- 12/2020: [CANSASfit-HISO-UT-6-3L] New module is now supported. 12/2020: [CANSASfit- HISO-T-8-2L] New module is now supported. 12/2020: [CANSASflex-L-HISO8] Connection diagrams have been updated or added for the following variants: -HISO8-4L, -HISO8-8L, -HISO8-T-2L, -HISO8-T-8L 12/2020: [CANSASflex-HISO-HV4] Connection diagrams updated. 12/2020: [CANSASfit-UTI6-TEDS] Write sensor is not supported and hidden in the CANSAS user interface. 12/2020: [DBC Export] Default receiver/sender name has been changed to "imc" and is now effective for all Windows users of a PC. 12/2020: New manual edition. Release V2.2 Rev 2 dated July 8 2020 -------------------------------------------------------------------------------- 07/2020: [CANSASfit/T-10] The unit of the measured values is now set to " C". 07/2020: [CANSASfit/UTI-6-TEDS] UTI-6 variant with TEDS support added. 06/2020: [CANSASfit/ENC-6] All units are now listed without quotation marks. 06/2020: [CANSAS\DAC8] Output channel can be switched passive again (-> branch No CAN-Bus message"). Fixed analog value can now be set to "0". 06/2020: [Interface driver] IXXAT driver version VCI 4.0925.0 for Windows 10, 8, 7 added to the installation CD. Release V2.2 Rev 1 dated May 14 2020 -------------------------------------------------------------------------------- 04/2020: [CANSAS\HISO-HV4] New module type added. 04/2020: [ CANSAS\B1] Now supports scaling factor and offset for 32-bit floating point numbers. 05/2020: [CANSAS\UNI-8] Setting of the 0.5mV/V measuring range was not retained. 05/2020: [CANSAS software] Receiver for DBC export is now entered correctly. 05/2020: Additional quotation marks removed in the scaling setting dialog.